搜索结果: 1-15 共查到“flow injection”相关记录22条 . 查询时间(0.132 秒)
Reverse flow injection analysis of trace amounts of anionic surfactants in seawater without liquid–liquid extraction
anionic surfactants reverse flow injection analysis seawater spectrophotometry
font style='font-size:12px;'>
2015/3/3
In order to control the pollution by anionic surfactants in seawater, a simple, accurate and sensitive reverse flow injection (rFIA) spectrophotometric method for the determination of anionic surfacta...
Flow Injection Spectrophotometric Determination of Hydrazine in Environmental Water Samples
Flow Injection Hydrazine Spectrophotometry
font style='font-size:12px;'>
2011/12/14
A simple, accurate, sensitive and selective flow injection spectrophotometric method for rapid determination of amounts of hydrazine was proposed in this paper, which was based on p-dimethylamino-benz...
Flow-Injection Determination of Vanadium in Seawater Samples with Acidic Potassium Permanganate Chemiluminescence
Vanadium Seawater Samples Acidic Potassium Permanganate Chemiluminescence
font style='font-size:12px;'>
2010/9/17
Chemiluminescence from the vanadium and potassium permanganate reaction was studied under acidic conditions to develop a sensitive method for vanadium determination using the formaldehyde enhancement ...
Flow Injection Determination of Iron Ions with Green Tea Extracts as a Natural Chromogenic Reagent
Iron Ions Green Tea Extracts Natural Chromogenic Reagent
font style='font-size:12px;'>
2010/9/20
A green chemistry system that utilizes natural extract as an alternative reagent for determination of metal ions has been investigated. The extract of green tea, a common beverage, is used for quanti...
Flow-Injection On-line Electrochemical Separation/Determination of Ions Using a Two-Step Oil/Water-Type Flow Cell System
Flow-Injection On-line Electrochemical Separation/Determination a Two-Step Oil/Water-Type Flow Cell System
font style='font-size:12px;'>
2010/9/19
A flow system for electrochemical separation and detection of ions was constructed by connecting two oil/water (O/W)-type flow cells, in which a long polarizable O/W interface was formed at the inner ...
Sensitive Assay for Carvedilol in Tablets and Spiked Human Plasma Using a Flow-Injection Chemiluminometric Method
carvedilol chemiluminescence flow injection Tris (2, 2’‑ bipyridyl) ruthenium (II)
font style='font-size:12px;'>
2009/4/20
A simple and sensitive chemiluminometric method using flow injection (FI) is developed for the determination of carvedilol, based on the reaction of carvedilol with tris (2, 2’-bipyridyl) ruthenium (...
A mushroom tissue-based flow-injection fluorescence system for the determination of isoprenaline
font style='font-size:12px;'>
2007/7/28
专著信息
书名
A mushroom tissue-based flow-injection fluorescence system for the determination of isoprenaline
语种
英文
撰写或编译
作者
Zouping Wang,Zhujun Zhang,Zhifeng Fu
第一作者单位
出版社
Anal Chim Acta 2003,494,1-2:63-7...
Sensitive Flow-injection Chemiluminescence Determination of Metformin Based on N-bromosuccinimide- Fluorescein System
font style='font-size:12px;'>
2007/7/28
专著信息
书名
Sensitive Flow-injection Chemiluminescence Determination of Metformin Based on N-bromosuccinimide- Fluorescein System
语种
英文
撰写或编译
作者
Zhouping Wang,Zhujun Zhang,Zhifeng Fu
第一作者单位
出版社
Anal。 Lett...
Flow-injection inhibition chemiluminescence determination of indapamide based on luminol-ferricyanide reaction
font style='font-size:12px;'>
2007/7/28
专著信息
书名
Flow-injection inhibition chemiluminescence determination of indapamide based on luminol-ferricyanide reaction
语种
英文
撰写或编译
作者
Zhouping Wang,Zhujun Zhang
第一作者单位
出版社
J. Pharm. Biomed. Anal. 2004...
Flow-injection Electrochemiluminescence Detecting Rifampicin Based on lts Sensitizing Effect
font style='font-size:12px;'>
2007/7/28
专著信息
书名
Flow-injection Electrochemiluminescence Detecting Rifampicin Based on lts Sensitizing Effect
语种
英文
撰写或编译
作者
Ma,Hong-Yan,Zhang,xing-wang,Zhang,Zhu-jun
第一作者单位
出版社
Chinese Journal of Chemistry,20...
On-line galvanic cell generated electrochemiluminescence determination of acyclovir based on the flow injection sampling
font style='font-size:12px;'>
2007/7/28
专著信息
书名
On-line galvanic cell generated electrochemiluminescence determination of acyclovir based on the flow injection sampling
语种
英文
撰写或编译
作者
Jiagen Lv,Lirong Luo,Zhujun Zhang
第一作者单位
出版社
Analytica C...
Determination of procaine hydrochloride using flow injection inhibitory chemiluminescence
font style='font-size:12px;'>
2007/7/28
专著信息
书名
Determination of procaine hydrochloride using flow injection inhibitory chemiluminescence
语种
英文
撰写或编译
作者
Nianbing Li,Yuwu Chi,Jian Wang,Jianping Duan,Guonan Chen
第一作者单位
出版社
Luminescence, 18, 1...
N-bromosuccinimide -fluorescein based sensitive flow-injection chemiluminescence determination of phenformin
font style='font-size:12px;'>
2007/7/28
专著信息
书名
N-bromosuccinimide -fluorescein based sensitive flow-injection chemiluminescence determination of phenformin
语种
英文
撰写或编译
作者
Zhouping Wang,Zhujun Zhang
第一作者单位
出版社
Anal. Sci. 2004, 20 (2): 319-3...
A flow-injection ultrafiltration sampling chemiluminescence system for on-line determination of drug-protein interaction.
font style='font-size:12px;'>
2007/7/28
专著信息
书名
A flow-injection ultrafiltration sampling chemiluminescence system for on-line determination of drug-protein interaction.
语种
英文
撰写或编译
作者
Zhouping Wang,Zhujun Zhang,Zhifeng Fu
第一作者单位
出版社
Anal B...
Speciation of Manganese Using a Pneumatic Flow Injection Analysis-Tandem Spectrometer System
Pneumatic flow injection analysis tandem spectrometer manganese speciation UV-Vis spectrometer flame atomic absorption spectrometer
font style='font-size:12px;'>
2010/4/16
A pneumatic flow injection-tandem spectrometer system, without a delivery pump, was used for the speciation of manganese (Mn). In this system the suction force of the pneumatic nebulizer of a flame at...